Send Message

Electrical Heater 7.5kw Fluidized Bed Coating Equipment

Basic Information
Place of Origin: CHINA
Brand Name: YIGAN
Certification: CE
Model Number: FLP
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: Packed in film firstly, and then reinforced with wooden case for outer packing
Delivery Time: 20 working days after received your payment
Supply Ability: 20 sets per month
Product Name: Fluid Bed Coater/fluid Bed Coating Equipment Feature: Electrical Heater
Application: Lab Use Processing Object: Granule
Feed Mode: By Feed Pump Function: Mixing,drying,coating
Standard: CE/ROHS/FCC/SGS
High Light:

7.5kw organic fertilizer granulator

,

7.5kw Fluidized Bed Coating Equipment

FLP-5 9kw electrical heater fluid bed coating equipment for lab use

Specifications

FLP-5 9kw electrical heater fluid bed coating equipment for lab use is widely used in coating of powder,granule,pellet,enteric releasing,slow and control releasing,and coating of smell covering

Features

 

Integrating mixing, pelleting, granulating and drying in its one body, reducing the process of technics and contamination and the workload of workers.

The surface of the equipment is neat and lubricity inside and outside, free of blind corner and easy to clean.

 

Applications

 

Powder or mother granule in rotated fluibed will undertaken the action of air flouting force in ring gap, rotating centrifugal force and gravity itself and appear cycle rope strain shape. Adhesive or coat liquid will be sprayed into the layer of material to form pellet with high degree of ball or continuous and uniform coating film.

hape material.

                                                  Electrical Heater 7.5kw Fluidized Bed Coating Equipment 0

 

Technical Parameters

 

Name FLP3 FLP5 FLP10 FLP15 FLP30 FLP60 FLP120
Dia of container mm 400 600 700 800 1000 1200 1500
Productive capacity kg/batch 0.75-3 1.2-5 2.5-10 3-15 7.5-30 15-60 30-120
Power of fan kw 3 4 5.5 7.5 7.5 11 18.5
Steam Pressure Mpa 0.4-0.6
  Consumptio n m3/min 6kw 20 35 42 60 160 240
compressed air Pressure Mpa 0.6
Consumptio n m3/min 0.3 0.4 0.6 0.6 0.9 1.1 1.5
Noise dB The noise at fan separated place should be less than 75dB

 

 

 

 

 

 

Contact Details
Mrs. Saffi Wang

Phone Number : 0086 88908521

WhatsApp : +8613806125772